FRP 加固砌体房屋原型的有限元分析
摘要
关键词
参考
[1] Milani, G., Shehu, R., & Valente, M. (2017). Possibilities and limitations of innovative retrofitting for masonry churches: Advanced computations on three case studies. Construction and Building Materials, 147, 239-263. [2] Bednarz, Ł. J., Jasieńko, J., Rutkowski, M., & Nowak, T. P. (2014). Strengthening and long-term monitoring of the structure of an historical church presbytery. Engineering Structures, 81, 62-75. [3] Cosenza, E., & Iervolino, I. (2007). Case study: seismic retrofitting of a medieval bell tower with FRP. Journal of Composites for Construction, 11(3), 319-327. [4] Ceroni, F., & Prota, A. (2009). Case Study: Seismic Upgrade of a Masonry Bell Tower Using Glass Fiber-Reinforced Polymer Ties. Journal of Composites for Construction, 13(3), 188-197. Saleem, M. U., Numada, M., Amin, M. N., & Meguro, K. (2016). Seismic response of PP-band and FRP retrofitted house models under shake table testing. Construction and Building Materials, 111, 298-316. [6] Foraboschi, P., & Vanin, A. (2013). New methods for bonding FRP strips onto masonry structures: experimental results and analytical evaluations. Composites: Mechanics, Computations, Applications: An International Journal, 4(1). [7] Kadam, S. B., Singh, Y., & Li, B. (2014). Strengthening of unreinforced masonry using welded wire mesh and micro-concrete–behaviour under in-plane action. Construction and Building Materials, 54, 247-257. [8] Choudhury, T., Milani, G., & Kaushik, H. B. (2015). Comprehensive numerical approaches for the design and safety assessment of masonry buildings retrofitted with steel bands in developing countries: The case of India. Construction and Building Materials, 85, 227-246. [9] Puri, V., Chakrabortty, P., Anand, S., & Majumdar, S. (2017). Bamboo reinforced prefabricated wall panels for low cost housing. Journal of Building Engineering, 9, 52-59. [10] Iyer, S. (2002). Guidelines for building bambooreinforced masonry in earthquake-prone areas in India (Doctoral dissertation, University Of Southern California). [11] Zhang, S., Yang, D., Sheng, Y., Garrity, S. W., & Xu, L. (2017). Numerical modelling of FRPreinforced masonry walls under in-plane seismic loading. Construction and Building Materials, 134, 649-663. [12] Monaco, A., Minafò, G., Cucchiara, C., D'Anna, J., & La Mendola, L. (2017). Finite element analysis of the out-of-plane behavior of FRP strengthened masonry panels. Composites Part B: Engineering, 115, 188-202. [13] Batikha, M., & Alkam, F. (2015). The effect of mechanical properties of masonry on the behavior of FRP-strengthened masonry-infilled RC frame under cyclic load. Composite Structures, 134, 513-522. [14] Grande, E., Imbimbo, M., & Sacco, E. (2013). Finite element analysis of masonry panels strengthened with FRPs. Composites Part B: Engineering, 45(1), 1296-1309. [15] Marcari, G., Oliveira, D. V., Fabbrocino, G., & Lourenço, P. B. (2011). Shear capacity assessment of tuff panels strengthened withFRP diagonal layout. Composites Part B: Engineering, 42(7), 1956-1965. [16] Indirli M., Bati S.B., Tralli A.M. Verifica sperimentale del dispositivo in SMA in serie con rinforzi in FRP: prove preliminari. ENEA Report 2011. [17] Lubliner J, Oliver J, Oller S, Oñate E. A plasticdamage model for concrete (1989). International Journal of Solids and Structures 1989;25:299-326. [18] Lee J, Fenves GL. Plastic-Damage Model for Cyclic Loading of Concrete Structures (1998). Journal of Engineering Mechanics 1998;124:892-900. [19] Valente M, Milani G. Damage assessment and collapse investigation of three historical masonry palaces under seismic actions. Engineering Failure Analysis 2019;98:10-37. [20] Valente M, Barbieri G, Biolzi L. Seismic assessment of two masonry Baroque churches damaged by the 2012 Emilia earthquake. Engineering Failure Analysis 2017;79:773-802. [21] Toopchi-Nezhad, H., Tait, M. J., & Drysdale, R. G. (2009). Shake table study on an ordinary low-rise building seismically isolated with SU-FREIs (stable unbonded-fiber reinforced elastomeric isolators). Earthquake Engineering & Structural Dynamics, 38(11), 1335-1357.
Refbacks
- 当前没有refback。